站内搜索
|
详细信息 Product Name: Commercial and Residential Rooftop Air Handling Unit Model NO.: EST15MU6 Condition: New Certification: ISO, CE Lifetime: >20 years Mounting: Floor Standing Application Fields: HVAC Noise Level: Low Operating Voltage: 380/400 VAC Corrosion Durability: Higher Air Tube Material: Galvanized Sheet Type: Air Handling Unit Ahu Construction: 25mm/ 50mm/ 75mm Double Skin Ahu Panels: Painted Steel, Gi, Ss Panels Cooling/ Heating Coil 2: Copper Tube with Copper Fins (Cu/Cu), Gi/SUS frame Control: Option for PLC, Ddc Cooling/ Heating Coil 1: Copper Tube with Aluminium Fins (Cu/Al), Gi/SUS Fr Optional 1: VSD, VFD Fan: Belt Drive Centrifugal Fan, Plug Fan, Ec Fan Side Sliding Filter with Tracks: Yes PU Foam Insulation: 43-48kg/M3 Cold Bridge Free Design: Yes Filters: Pre-Filter, Bag Filter, HEPA Filter Ahu framework: Aluminum base: C-Channel Hot DIP base Optional 2: Heat Recovery Wheel Optional 3: Ep, Chemical Filter, Plasma Sterilizer, Ak Trademark: ESACIR Transport Package: Standard Package Specification: CE Origin: Guangdong, China HS Code: 8415830000 Product Description 1.Eurostars air handling unit and air handler features---High efficiency and energy saving:the crossflow plate heat exchanger pre-cools the exhaust air and transfer that heat into the fresh air for reheat, the heat exchange efficiency of exhaust air and fresh air more than 90%, the exchanger can reduce the required air conditioning tonnage of fresh air and overall energy consumption by over 60~90%---No pollution heat exchange:the exchanger is made with modular structure, aluminum extruded sections, aluminum coated zinc plate, all the joints sealed by sealant, avoid cross-polluted---Operation efficiency and quietly, VFD fan available---Outstanding reliability and performance---Anti-corrosion stainless steel structure, clean hygienic design, durable epoxy resin coated coil available---Configured flexibly, numerous options for customization: cooling, dehumidifying, heating and air clean function optional2.Eurostars Air handler,air handling unit, ahu applicationEUROSTARS air handling unit can cool, dry, heat, humidify, filter and purify air with silencer function. It can be widely applied in the places where the air needs to be conditioned in a centralized way, such as shopping malls, hotels, office buildings and stadiums, as well as other purification air-conditioning places, such as hospital operating rooms, pharmaceutical, tobacco, food, precision instruments manufacturing rooms.3.Air handler technical data, Assembly drawing diagram and photoModular Air Handling UnitModelEST4R4MU46MU49MU412MU415MU418MU422MU425MU430MU435MU440MU445MU450MU46R4MU66MU69MU612MU615MU618MU622MU625MU630MU635MU640MU645MU650MU6Air Flow*1000CMH46912151822253035404550CoolingCoil SectionSensible Capa.(KW)/4R26405876102121131174201235274308348Sensible Capa.(KW)/6R32497794122146185218258302349383433Heating SectionE-Heating Capa.(KW)1218303645546072729090108108Humidifying SectionHumidifyingCapa.(Kg/h)5101315152530454560606075Fan-motorSectionESP(Pa)600600600600600600800800800800800800800Motor Power(KW)2.245.57.51111151518.518.5223030Mixing Section√√√√√√√√√√√√√Pre-filter Section√√√√√√√√√√√√√Cooling Coil Section√√√√√√√√√√√√√Eliminator Section√√√√√√√√√√√√√Elec-heating Section√√√√√√√√√√√√√Humidifying Section√√√√√√√√√√√√√Fan-motor Section√√√√√√√√√√√√√Diffusing Section√√√√√√√√√√√√√Medium-filter Section√√√√√√√√√√√√√Supply Air Section√√√√√√√√√√√√√NOTE: 1. Return air: Cooling: Air in 27ºC DB, 19.5ºC WB,Chilled water in/out:7ºC /12ºC; 2. Technical parameters are subject to be revised without prior notice.4.Eurostars air handling unit ,air handler range or series-Horizontal ceiling ducted air handling unit-Horizontal concealed air handling unit-Vertical concealed air handling unit-Vertical exposed air handling unit-Modular Modulus Air Handling Unit-multi-function air handling unit5.Components-air handling unit or air handlerCasing Panel and Insulation• Double skin construction is provided by sandwich type panels comprising inner and outer painted steel skins and polyurethane foam with minimum 48kg/m3 density, providing agood thermal and acoustical performance• The gasket liner between the panels and frame ensures the air leakage rate to comply with GB/T 14294 clean air conditioningrequirement• The factory painted steel sheet covered with 6 insulation coatings, complies to 500h salt spray testing, showing an excellent corrosion protection performanceframe•Penta-post extra heavy gauge aluminum profiles and strongfiber-reinforced PE corner connection forming the structural frame• superior mechanical strength and rigidity to the unit frame and to prevent any buckling or deformation• Thermal bridge free design, the profiles filled with polyurethane foam for insulation• Anodizing surface treatment for profiles, corrosion-resistant• Stainless steel frame availableSight Glass Service Door• Double skin structure, inner panel is made of stainless steel, and outer panel is made of painted steel sheet• Positive and negative access door, ensures the airtight of unit• Convenient to check the running status of the unit• Double sealing, no air leakage• Built-in multi-point fastening locks make the panel evenly stressed, preventing air leakage and loss of energy efficiency of the unitHot-Dip Galvanized base channelOffer Rigid base Channel protect unit and save installation costFan and motor •NICOTRA centrifugal Fan or other brand fan;•Double inlet•Electric motor driven•Back curved or front curved•low noise, high efficiency, stable operation, low vibration, good strength, low bearing temperature rise, and wide working temperature and humidity range.•Customized configuration of the motor selected high-quality brand-name motor, smooth operation, low noise, long service life, and can be equipped with a specified brand of motor or motor insulation, protection level people according to user requirements, to meet the needs of different occasions.•EC Fan is optional• plug fan is optionalVibration Eliminator• To reduce the transmission of vibration and noise, fan and motor are installed on an independent complete base frame• The complete base frame is isolated by deflection type spring isolators• This unique structure not only reduce the vibration and noise, but also protect fan and motor during transportationCooling CoilCooling Coil is used to cool and dehumidify the air.Both DX (direct expansion) cooling and CW (chilled water) cooling coils are available for use depending on the system design.These coils are arranged in rows with different fin spacing.Aluminum fins and copper tubes are used in the design of the coils.The corrosion resistance hydrophilic fins are alsoused due to its lower cost and lower resistance to the air velocity.PTC Electric Heating•Constant temperature heating•Virtually unlimited life•Low electricity consumption and very low in cost•No electrical noise•The higher the temperature, the more electricity efficient•Avoid burning when in contact with combustible materialsElectrostatic Precipitator(optional)• Adsorb and remove particles less than 0.01 micron in the air• Improve indoor air quality•ESP applies energy only to the particulate matter being collected and therefore is very efficient in its consumption of energyElectrode Humidifier•Cylinder monitor system ensures more efficiency, better energy saving and stable result•Drainage pump ensures the humidifying process accurate and stable•Clog protection system ensures to avoid water overflow•Water temperature control system makes sure the drainage pipe won't be damaged by hot water•Anti-electric leakage system makes operation and maintenance safe and secureFiltersFilters are to remove particles and contaminants of various sizes from the air. The type of air filter being used will very much depend on the application of the system.Panel Filter is a flat and rectangular in shape and provides a minimum low efficiency filtration which is acceptable to the air conditioning industry. The high velocity filteris arranged vertically whereas the low velocity filter is arranged in V shape. Typical air velocity that moves through the filters is in the range of 2-3 m/s.HEPA Filter is very efficient and is able to achieve efficiencies up to 99.97%, removing minute particles and airborne bacteria from the air. It is usually used in clean roomapplications such as semiconductor production floor, operating theaters and critical processes.Electrostatic Filter is used to remove particles from the air by using highly charged electrodes that ionized the air.Bag Filter is able to remove dust particles and is thrown away after use.Roll Filter is used for high velocity filtration where the used part is rolled up automatically/manually.Differential pressure meter Brand name:PRECISEDifferential pressure meter( with signal transfer) can be configured acccording to user requirements.Air damper•Variable discharge air volume•Discharge damper with axial fan, independent control•High efficiency•Manual damper availableHeat Wheel Heat Exchanger(optional)• Highly efficient energy-savingrotary heat exchanger• Energy recovery rates between 70-90%• Summer application is dehumidification of warm and humid supply air to reduce the energy consumption of the down stream cooling equipment.• Winter operation recovers moisture from the exhaust air to reduce the humidification load.Stainless Steel Drain Pan• Slop type design, no drain water carryover and keep the pan dry• Avoid the micro-organisms growth inside the drain panAntimicrobial Drain Pan is offered as option• SteriTouch technology Drip Pan Coating• Antimicrobial surface• Good exterior durability and corrosion resistance• Excellent adhesion• Non-toxic, comply with BS476 part 7Electrical control cabinet(optioanl)•According to the requirements and functions of the unit to design the control console or cabinet•Auto control each section of the unit to make sure the temperature, humidity and cleaness•High quality and international brand electrical elements•DDC and PLC available6.Why choose us?Eurostars offers One Stop Solutions for:•Pharmaceuticals industry•Electronics industry•Automobile industry•Printing and food industry•Commercial building•VOC treatment and environment protection•Indoor air quality•Marine ventilation7.FAQ1:Are you a factory?--- Yes, we are a professional manufacturer for more than 13 years2:How do you check the goods?--- We inspect all the materials when they arrive, and have spot inspection during production process. All goods will be tested and double inspected before delivery, providing 100% guarantee for clients.3:How to select the suitable models?---The parameters above is just for your reference. We need you to provide us the air flow, ESP or TSP, cooling capacity, heating capacity or application for our team to design the suitable unit for you.8.Customer visit us9.Air handling unit,air handler delivery or container loading10.Installation instruction or installation photo, project photos
|