首页 > Products > Air Handling Systems Galvanized Frame FFU HEPA Fan Filter Unit
Air Handling Systems Galvanized Frame FFU HEPA Fan Filter Unit
单价 $300.00 / Piece对比
询价 暂无
浏览 275
发货 Chinaguangdongshenzhen
库存 2000Piece
过期 长期有效
更新 2020-08-18 14:27
 
详细信息
Product Name: Air Handling Systems Galvanized frame FFU HEPA Fan Filter Unit Model NO.: EST7VC6 Condition: New Certification: ISO, CE Lifetime: >20 years Mounting: Ceiling Mount Application Fields: Air-Conditioning (HVAC)System Noise Level: Low Operating Voltage: 380/400 VAC Corrosion Durability: Higher Air Tube Material: Galvanized Sheet Type: Air Handling Unit Ahu Construction: 25mm/ 50mm/ 75mm Double Skin Filters: Pre-Filter, Bag Filter, HEPA Filter PU Foam Insulation: 43-48kg/M3 Ahu framework: Aluminum Cooling/ Heating Coil 1: Copper Tube with Aluminium Fins (Cu/Al), Gi/SUS Fr Optional 1: VSD, VFD Side Sliding Filter with Tracks: Yes base: C-Channel Hot DIP base Fan: Belt Drive Centrifugal Fans or Hygiene Plug Fan Ahu Panels: Painted Steel, Gi, Ss Panels Optional 3: Ep, Chemical Filter, Plasma Sterilizer, Ak Control: Option for PLC, Ddc Cooling/ Heating Coil 2: Copper Tube with Copper Fins (Cu/Cu), Gi/SUS frame Optional 2: Heat Recovery Wheel Cold Bridge Free Design: Yes Trademark: ESACIR Transport Package: Standard Package Specification: CE Origin: Guangdong, China HS Code: 8415830000 Product Description 1. Eurostars air handling unit and air handler featuresThe AHU is designed for hospital/ pharmaceutical/ cleanroom.ect• Supply Precious Temp and RH% Clean Air• Large air volume, higher cooling capacity , heating capacity and humidifying capacity• Multi-sections serviceable filter type for PM2.5 Treatment• Built-in Microprocessor Control Console AHU with operation data display (compatible with wireless control)• Serviceable Energy Saving EC Fan• Operation efficiency and energy saving• Outstanding reliability and performance• Configured flexibly, numerous options for customization• HVACR and Industrial Clean Air application2.Eurostars Air handler,air handling unit, ahu applicationEurostars air handlers widely used in stadium, exhibition centers, airport, large station, as well as in all kinds of factories, such as car, electronics, textile, medicine, tobacco, alternator, and precise instrument.3.Air handler technical data, Assembly drawing diagram and photoVertical Air Handling Unit(Return Air Condition-4 Rows)ModelAir FlowTotalPressurePower InputReturn AirCooling CapacityHeating CapacityWater FlowWater ResistanceWater inlet/outlet pipe Diameter*1000CMHPakWkWL/minkPaDNEST3VC433000.5518.726.153.412.732EST4VC443000.752636.274.414.732EST5VC453501.132.344.892.414.740EST6VC463501.537.352.1106.819.640EST7VC473501.543.961.312628.450EST8VC483502.250.670.5145.229.450EST10VC4103502.260.484172.818.650EST12VC412400373101.7209.420.650EST15VC415400498.6138.9282.622.565EST18VC4184005.5118.3165339.624.565EST21VC4214005.5139.5194.4400.230.465EST25VC4254007.5169.5236.3486.634.380Vertical Air Handling Unit(Return Air Condition-6 Rows)ModelAir FlowTotalPressurePower InputReturn AirCooling CapacityHeating CapacityWater FlowWater ResistanceWater inlet/outlet pipe Diameter*1000CMHPakWkWL/minkPaDNEST3VC633000.5524.331.569.616.732EST4VC643000.7531.640.990.628.440EST5VC653501.139.350.7112.230.440EST6VC663501.545.659.1130.814.750EST7VC673501.55469.9154.817.650EST8VC683502.262.881.318021.650EST10VC6103502.278.7101.8225.633.350EST12VC612400394.4122.1270.630.465EST15VC6154004119.3154.434238.265EST18VC6184005.5143.1185410.440.265EST21VC6214005.5167.8217.1480.641.280EST25VC6254007.5203.6263.4583.845.180NOTE: 1. Return air: Cooling: Air in 27ºC DB, 19.5ºC WB,Chilled water in/out:7ºC /12ºC; 2. Return air: Heaing: Air in 15ºC DB,Hot water in: 60ºC.4. Eurostars air handling unit , air handler range or series-Horizontal ceiling ducted air handling unit-Horizontal concealed air handling unit-Vertical concealed air handling unit-Vertical exposed air handling unit-Modular Modulus Air Handling Unit-multi-function air handling unit5. Components-air handling unit or air handlerCasing Panel and Insulation• Double skin construction is provided by sandwich type panels comprising inner and outer painted steel skins and polyurethane foam with minimum 48kg/m3 density, providing agood thermal and acoustical performance• The gasket liner between the panels and frame ensures the air leakage rate to comply with GB/T 14294 clean air conditioningrequirement• The factory painted steel sheet covered with 6 insulation coatings, complies to 500h salt spray testing, showing an excellent corrosion protection performanceframe•Penta-post extra heavy gauge aluminum profiles and strongfiber-reinforced PE corner connection forming the structural frame• superior mechanical strength and rigidity to the unit frame and to prevent any buckling or deformation• Thermal bridge free design, the profiles filled with polyurethane foam for insulation• Anodizing surface treatment for profiles, corrosion-resistant• Stainless steel frame availableFamous Brand Blower and Motor•Energy saving Fan with low speed and low noise•Type: Direct driven / Belt driven Forward curve and backward curve Centrifugal fan and EC plug fan•Brand:Nicotra, Kruger, Deton, Yilidaavailable•Low noise long life Motor•Brand:Siemens, ABB and TecoavailableShock Absorber•High quality spring isolators•Protect the unit during transportation•Guard lock for fan start up•Eliminate shock and noise during operationCooling/ Heating Coil•Large coil face area with low air speed•Various anti-corossion coating for option, Electrophoresis and Heresite coating available•Type: Copper tube with Aluminium fins (Cu/Al), GI/SUS frame Copper tube with Copper fins (Cu/Cu), GI/SUS frame•Rows: 4R/6R(can be 2R+4R design)/8R (can be 4R+4R design)Copper Tube Protection•Every mounting hole filled up glass cement to prevent copper tube damage during transportation and operationHigh efficiency filterFilters are to remove particles and contaminants of various sizes from the air. The type of air filter being used will very much depend on the application of the system.Panel Filter is a flat and rectangular in shape and provides a minimum low efficiency filtration which is acceptable to the air conditioning industry. The high velocity filter is arranged vertically whereas the low velocity filter is arranged in V shape. Typical air velocity that moves through the filters is in the range of 2-3 m/s.HEPA Filter is very efficient and is able to achieve efficiencies up to 99.97%, removing minute particles and airborne bacteria from the air. It is usually used in clean room applications such as semiconductor production floor, operating theaters and critical processes.Electrostatic Filter is used to remove particles from the air by using highly charged electrodes that ionized the air.Bag Filter is able to remove dust particles and is thrown away after use.Roll Filter is used for high velocity filtration where the used part is rolled up automatically/manually.Stainless Steel Drain Pan• Slop type design, no drain water carryover and keep the pan dry• Avoid the micro-organisms growth inside the drain panAntimicrobial Drain Pan is offered as option• SteriTouch technology Drip Pan Coating• Antimicrobial surface• Good exterior durability and corrosion resistance• Excellent adhesion• Non-toxic, comply with BS476 part 7Electrical control cabinet(optioanl)•According to the requirements and functions of the unit to design the control console or cabinet•Auto control each section of the unit to make sure the temperature, humidity and cleaness•High quality and international brand electrical elements•DDC and PLC available6.Why choose us?Eurostars offers One Stop Solutions for:•Pharmaceuticals industry•Electronics industry•Automobile industry•Printing and food industry•Commercial building•VOC treatment and environment protection•Indoor air quality•Marine ventilation7.FAQQ:What is air handler?A: An air handler, or air handling unit (often abbreviated to AHU), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning (HVAC) system.Air handlers usually connect to a ductwork ventilation system that distributes the conditioned air through the building and returns it to the AHU. Sometimes AHUs discharge (supply) and admit (return) air directly to and from the space served without ductwork.Small air handlers, for local use, are called terminal units, and may only include an air filter, coil, and blower; these simple terminal units are called blower coils or fan coil units.A larger air handler that conditions 100% outside air, and no recirculated air, is known as a makeup air unit . An air handler designed for outdoor use, typically on roofs, is known as a packaged unit or rooftop unit .Q:What information do you need to provide in order to get a quotation?A:Generally, we need to know following items:-Cooling Capacity in KW or RT or Btu-Cold water conditions if available is better- Local ambient temperature conditions-Application-Electrical power supply, such as 380V-3Phase-50HZ or 440V-3Phase-60HZ or others.If can not give full answers for above items, we can via another way, such as room or building drawing,application,etcQ:Can I have a sample for testing before ordering products?A:Yes, you can.And you are warmly welcomed to visit our factory before PO.Q:What is the warranty of products?A:Warranty: 12~24 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines8.Customer visit us9.Air handling unit,air handler delivery or container loading10.Installation instruction or installation photo, project photos