Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

Shenzhen Eurostars Technology Co., Ltd.  

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:John
  • 电话:86-755-23205348
  • 传真:86-755-23205349
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > R404A Copeland Scroll Compressor Condensing Unit
R404A Copeland Scroll Compressor Condensing Unit
单价 $600.00 / Piece对比
询价 暂无
浏览 147
发货 Chinaguangdongshenzhen
库存 1200Piece
过期 长期有效
更新 2020-08-18 14:25
 
详细信息
Product Name: R404A Copeland Scroll Compressor Condensing Unit Model NO.: ESSA-07NJSGY Condition: New Certification: ISO, CE Cooling Method: Air Cooling Temp. Range: -15deg C~-5 Deg C Temperature Type: MID Temperature Compressor Brand: Emerson Copeland Standard Power Supply: 380~415V-3phase-50Hz Others Kind of Power Supply: 220/380/440/460V-3phase-60Hz Refrigerant Gas: R22/R404A/R507A Product Structure: Open Type or Box Type Trademark: ESACIR Transport Package: Standard Export Package Specification: CE Origin: Guangdong, China HS Code: 8418692090 Product Description 1. Cold room or cold storage Condensing unit with Copeland Scroll Compressor introduction and technical dataTemperature: 5~15 ºC ,-5~-5ºC, -15~5ºC and -18~-30ºCHorsepower: 2HP ~15HPCompressor type: Hermetic scrollCooling mode: air coolingPower supply: 380V/3Ph/50Hz,other kinds of power supply is optionalRefrigerant: R404A, R507A, R22**Mid temperature unitModelESSA~02NJSGY03NJSGY04NJSGY05NJSGY06NJSGYRoom Tem range (ºC)-15ºC~5ºCRefrigerantR404APower supply380/400/415V/3Ph/50 HZCompressor modelZB15KQEZB21KQEZB29KQEZB38KQEZB45KQECondenserFan qty11122Fan voltage (V)220220220220220Fan power(W)60606060*260*2Cap.&inputTe-5ºCCapacity(W)382057407790983011500Input(W)17602500331041804730Te-10ºCCapacity(W)30804680636080209380Input(W)18202510333042004760Te-15ºCCapacity(W)24303780513064807580Input(W)18802510333042104760Te-20ºCCapacity(W)18703020410051706050Input(W)19302520334042104770ModelESSA~07NJSGY08NJTGY09NJTGY10NJTGY13NJTGYRoom Tem range (ºC)-15ºC~5ºCRefrigerantR404APower supply380/400/415V/3Ph/50 HZCompressor modelZB48KQEZB58KQEZB66KQEZB76KQEZB95KQECondenserFan qty21112Fan voltage (V)220220220220220Fan power(W)60*2550550550460*2Cap.&inputTe-5ºCCapacity(W)1225015300171002040025000Input(W)521063607090892010700Te-10ºCCapacity(W)1020012400140001660020300Input(W)523063207050822010600Te-15ºCCapacity(W)81809480113001335016100Input(W)524063207020815010600Te-20ºCCapacity(W)6490752090001055012200Input(W)524063606980810010600ModelESSA~15NJTGYRoom Tem range (ºC)-15ºC~5ºCRefrigerantR404APower supply380/400/415V/3Ph/50 HZCompressor modelZB114KQECondenserFan qty2Fan voltage (V)220Fan power(W)460*2Cap.&inputTe-5ºCCapacity(W)29700Input(W)12650Te-10ºCCapacity(W)23540Input(W)12650Te-15ºCCapacity(W)18900Input(W)12650Te-20ºCCapacity(W)14350Input(W)126502. Condensing unit Main Components1. Compressor 2. Condenser 3. Oil heating 4. Suction& discharge valves 5. In/out pipe connection 6. H/L pressure gauge7. Sight glasses 8. Solenoid valve 9. Diaphragm type pressure switch 10. Liquid filter 11. Liquid receiver 12. liquid injection valve3. Cold room Condensing unit Features1) Copeland compressor is very reliable. It can work continuously for avery long time;2) Beautiful and durable appearance design, anti-collision and rain proof;3) Small space occupying, convenient for packing and transportation;4) Easy installation; floor stand or wall hung;5) Efficient and powerful fan which has big blast volume and low power consumption;6) Efficient heat transfer and ultra quiet design, easy operation.4. Condensing unit series:A: Wall/Roof mounted monoblock condensing unitB:Box type Emerson Copeland compressor condensing unitC: Box type Bitzer piston compressor condensing unitD: Open type Bitzer piston compressor condensing unitE:Open type Bitzer 2-stage compressor condensing unitF: Bitzer Semi-hermetic piston compressor racks condensing unitG: Bitzer Semi-hermetic screw compressor racks condensing unitH: Hanbell Semi-hermetic screw compressor racks condensing unit5.about USWe, EUROSTARS, which established in year 2006, is amodern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.Webiste 1:http://www.eurostarschina.com/Website 2:http://www.waterchiller-unit.com/Instagram:https://www.instagram.com/eurostars_aircon_refrigerationFacebook:https://www.facebook.com/pg/EurostarsHVACRYoutube:https://www.youtube.com/channel/UCFwKOPvrf0xSZdOzX0pB52A6.FAQQ: What information do you need to provide in order to get aquotation?A: Generally, for condensing unit we need to know following items:-Cooling Capacity,-Required cold room temperature or evaporating temperature-Water cooling system or air cooling system.-Compressor brand-Electrical power supply, such as 380V-3Phase-50HZ or 440V-3Phase-60HZ-Refrigerant, such as R22 or R404a-It is better there are local ambient temperature datasIf can not give full answers for above items, we can via another way, such as cold room dimension, application, etcIn order to providing asuitable solution and quotation for your application, please try as possible to let us know more your requirements and application, general enquiry requests:1. What's the frozen products?2. What's the temperature of cold room?3. What's the temperature of frozen products?4. What's the size of cold room?(L*M*H)5. What's the power supply?6. Which refrigerant do you need? R22 or R404A?7. Which type unit you prefer? Scroll type, piston type or screw type?8. Other requirements?7. Installation instructions and project photo1) The unit should be fixed at the site where the air is easy to flow, and far away from heat source;2) In the storage building, the fixing hole for the unit should be made before the installation. The side of the hole should be made of wood, strong enough to support the unit.3) Good quality wood should be embedded at the hole for bold fixing;4) Fix the unit on the body of the storage room with bolts;5) Seal the hole around the unit with sealing material;6) Drainage pipe fixing:Fix the drainage pipe on the drainage mouth of the evaporator with pipe clam, ensure the direction is correct and the water could flow smoothly;7) Electrical system fixing:(1)Check the conformity of voltage the main power supply to that of name plate, the tolerance is ±10%;(2)Air switch is required to ensure safety and flexibility.(3)Grounding must be reliable;8)Trial operation of the unit(1)Verify that the electrical connection is correct before start the unit;(2)Add water to the pan of evaporator until there can be see water comes out from the of drainage pipe at the condenser side;(3)Close the air switch, one minute later, the indicator of the fan and refrigeration on the control panel will be on, means the operation is normal. Keep watch until operation is stable.8. Product package and deliver:A:For cold room machine:Standard package fwith plywood, the unit can be well protected, it is with pallet on the bottom for easy transportation.,the unit can be well protected ,suitable for container shipment.B:For cold room panel:Plastic film for panel, Each panel is well wrapped with plastic film respectively, the corner is protected with brown paper.