站内搜索
|
首页 > Products > High Efficiency Commercial Industrial Use Air to Water Building Heating and Cooling Heat Pump
详细信息 Product Name: High Efficiency Commercial Industrial Use Air to Water Building Heating and Cooling Heat Pump Model NO.: ESSA Series Heat Source Type: Air Source Heat Pump Working Medium: R407c, R410A Certification: ISO9001, CE DC Inverter: Optional Compressor: Emerson Copeland Evi Series Working Ambient Termp.: -25deg C~43deg C Power Supply: 50Hz, 60Hz(Optional) Water Side Heat Exchanger: Tube in Shell Type/Plate Type(Optional) Warranty: 2 Years, 18 Months, 1 Year Air Side Heat Exchanger: Blue Aluminum Fin Arround Copper Tube Overseas Service: Available Throttle Unit: Electric Expansion Valve OEM,ODM: Available Power Source: Electric Housing Material: Galvanized Steel Structure: Monoblock Type Application: Cooling and Heating Refrigerant: R407c, R410A(Optional) Trademark: ESACIR Transport Package: Standard Export Package Specification: CE Origin: Guangdong, China HS Code: 8418692090 Product Description 1.Application of Air Source Heat PumpEVI low temperature air source heat pumps absorb low-grade heat energy from the air to provide domestic/commercial heating or hot water. They can also function as cooling devices in summer. These cold climate heat pumps are developed using the Enhanced Vapor Injection (EVI) compressor technology and high-efficiency eco-friendly refrigerant, which ensures that the units can work normally at - 25ºC and supply heating in cold areas.In some areas, the lowest temperature in winter can reach minus 25ºC. Under such a low temperature environment, it is difficult for ordinary air source heat pumps to maintain a good heating capacity. Low ambient temperature will lead to severe frosting of air source heat pumps, resulting in inability to start or unstable heating. It is recommended to use EVI air source heat pumps in cold weather. They apply special low temperature technology, special low temperature compressors and low temperature refrigerants to ensure normal start-up, stable operation and efficient heat supply under a low temperature environment. Now they are widely used in cold climate for heating and hot water supply.Eurostars EVI Air source heat pumps can supply domestic/commercial room heating and cooling.Wide Range of Applications:air to water heat pumps could meet the space heating and cooling requirements of different places, such asvillas, families, schools, factories, hotels, hospitals, sauna centers, greenhouses, flower gardens, farms, etc.2.Eurostars Air Source Heat Pump Features:1) EVI compressor special designed for high COP (Coefficient of Performance): 4.0even in bad weather condition or area. 2) base frame and external panels made of galvanized powder coated steel 3) Water exchanger equipped with high efficiency tube in shell heat exchanger 4) Reliable compressor with R407C/R410A refrigerant 5) Stable water flow switch & backflow proof. 6) Fully sealed control box with water proof level IPX4 7) Intelligent microprocessor control systems 8) Air exchanger (fin-coil) with hydrophilic coating 9) Thermostatic heating element for evaporator, anti-frosting10)Every capillary tube of SANHUA/DANFOSS/EMERSON expansion valve full-covered by silicon/soft pipe refucing buffer friction, subtle vibration from compressor/fan, keeping strong as 15-20 years working life, even longer. 11)No need of auxiliary electrical heating and works well even at -25 ºC~30 ºC. 12) Lowest noise that fan motor & Copeland high efficient compressor, thermostability PE material with bond for soundproof & heat preservation. 3. Air Source Heat Pump Technical DataAir Source Heat Pump Unit(EVI Low Ambient Temp.Type) (Heating&Cooling)ModelESSA-05LHNESSA-05LHNESSA-05LHNESSA-05LHN2.5ES3ES4.5ES5ESWorking modeHeating&CoolingPower supply220V/50HZ380V/50HZ220V/50HZ380V/50HZHeatingAir DB/WB:7ºC/6ºC,water In/outlet:40ºC/45ºCHeating capacity (kW)7.68.414.015.2Input power(kW)2.322.584.384.75Current(A)11.14.721.08.7COP(W/W)3.283.263.203.20Water flow(m3/h)1.71.93.13.4Air: -10ºC/ ,Water In/outlet:40ºC/45ºCHeating capacity (kW)5.325.889.810.64Input power(kW)2.202.454.164.51COP(W/W)2.412.402.362.36Air: -20ºC/ ,Water In/outlet:40ºC/45ºCHeating capacity (kW)4.04.47.48.0Input power(kW)2.092.333.954.29COP(W/W)1.911.891.861.86Air: -25ºC/ , Water In/outlet:40ºC/45ºCHeating capacity (kW)3.94.26.47Input power(kW)2.352.524.404.30COP(W/W)1.661.671.451.63CoolingAir DB/WB:35ºC/24ºC,water In/outlet:12ºC/7ºCCooling capacity (kW)6.87.612.613.7Input power (kW)2.392.664.514.89Current (A)11.44.821.68.9COP(W/W)2.862.842.792.80Water flow (m3/H)1.51.72.83.1ModelESSA-10LHNESSA-10LHNESSA-10LHNESSA-15LHN5.5ES7ES2*5ES2*7ESWorking modeHeating&CoolingPower supply220V/50HZ380V/50HZ380V/50HZ380V/50HZHeatingAir DB/WB:7ºC/6ºC,water In/outlet:40ºC/45ºCHeating capacity (kW)17.519.030.440.8Input power(kW)5.465.949.512.75Current(A)26.110.817.323.2COP(W/W)3.23.23.23.2Water flow(m3/h)3.94.26.89.1Air: -10ºC/ ,Water In/outlet:40ºC/45ºCHeating capacity (kW)12.2513.321.2828.56Input power(kW)5.195.649.0312.11COP(W/W)2.362.362.362.36Air: -20ºC/ ,Water In/outlet:40ºC/45ºCHeating capacity (kW)9.210.016.021.4Input power(kW)4.935.368.5711.51COP(W/W)1.861.861.861.86Air: -25ºC/ , Water In/outlet:40ºC/45ºCHeating capacity (kW)7.591419Input power(kW)5.105.808.6012.00COP(W/W)1.471.551.631.58CoolingAir DB/WB:35ºC/24ºC,water In/outlet:12ºC/7ºCCooling capacity (kW)15.817.127.436.7Input power (kW)5.626.129.7913.13Current (A)26.911.217.823.9COP(W/W)2.802.792.802.80Water flow (m3/H)3.53.86.18.2ModelESSA-20LHNESSA-30LHNESSA-40LHN4*5ES4*7ES4*9ESWorking modeHeating&CoolingPower supply380V/50HZ380V/50HZ380V/50HZHeatingAir DB/WB:7ºC/6ºC,water In/outlet:40ºC/45ºCHeating capacity (kW)60.076.0115Input power(kW)18.723.7635.9Current(A)34.143.365.5COP(W/W)3.213.203.20Water flow(m3/h)13.417.025.7Air: -10ºC/ ,Water In/outlet:40ºC/45ºCHeating capacity (kW)4253.280.5Input power(kW)17.7722.5734.11Current(A)2.362.362.36Air: -20ºC/ ,Water In/outlet:40ºC/45ºCHeating capacity (kW)31.539.960.4Input power(kW)16.8821.4432.40Current(A)1.871.861.86Air: -25ºC/ , Water In/outlet:40ºC/45ºCHeating capacity (kW)2838Input power(kW)17.2024.00Current(A)1.631.58CoolingAir DB/WB:35ºC/24ºC,water In/outlet:12ºC/7ºCCooling capacity (kW)54.068.4103.5Input power (kW)19.2624.4736.98Current (A)35.144.667.4COP(W/W)2.802.792.80Water flow (m3/H)12.115.323.14.Air Source Heat Pump Main Components Introduction1)Copeland Compressor :High quality Scroll Compressor .2)Fan: Well selected axial fan motor combined with large fan blade, which provide heavy air blow at low rotate speed, reducing vibration and noise.3)Expansion Valve: SANHUA/Danfoss Expansion valve, with more precise control of refrigerant flow system, which optimize heat pump working capacity and efficiency under different ambient conditions.4)High Efficient tube in shell water side heat exchanger: Optimize design of both inner and outer screwed tube, it helps to increase heating exchange efficiency, and provide better heating capacity. The special design of liquid refrigerant circulating tube on the bottom of condenser ensures the heat pump system run smoothly in severe working condition.5)Air Side Heat exchanger: Blue hydrophilic fin and copper tube heat exchanger.6)Outfitting both liquid-storage & gas-liquid separator: Our heat pump outfitting both liquid-storage and gas-liquid separator ensures units run smoothly in different kinds of extreme hostile environment. 7)AC contactor & Thermal relay: High quality FUJ/Schneider /EATON or other brand contactor and thermal relay can freely turn on/off more times.8)Humanized PCB Design: Military level PCB components, intelligent controlling program reinforced a reliable operation of the heat pump unit. Special colored wiring design on the PCB provides great convenience in installation and further maintenance.9)Noise Isolated Material: Using high quality aerial noise isolated material, noise and vibration is avoided perfectly.5. EUROSTARS Heat Pump Range:(1) Water source heat pump(2) Geothermal source heat pump(3) Air source heat pump, including swimming pool heat pump(4) EVI air source heat pump (5) Split heat pump(6) DC Inverter heat pump6.about USWe, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services; One Stop Solution For Your Project:-- Project Consultation--Professional Customized Design & Planning--Supply Full Set Optimum Equipment & Accessary Accordingly--Whole Project Installation & Commissioning--Project Running Management, Engineer and Operator Training, Turnkey--Long Life Quality Assurance & Maintenance7.FAQQ:HOW TO SELECT A HEAT PUMP?How do users know what kind heat pump should buy? Such as air source heat pump, geothermal source heat pump, water source heat pump and swimming pool heat pump.A:--Air source heat pumpworking condition is from -25C to +43C. And the efficiency is affected by air temperature greatly. Colder weather, lower efficiency. So air source heat pump is suitable for the place where air temperature is above -25C.--Geothermal source heat pumpis: bury pipe in the garden ground, and water in the buried pipe deliver heat from soil to heat pump, heat pump transfer heat to house or hot water. Because soil temperature changes little and about 10C all the year, so that geothermal source heat pump gives constant and high efficiency all the time. If there is enough place to bury pipe, geothermal source heat pump is the best choice. But to install geothermal source heat pump cost higher than air source heat pump.Q:Why it can work at-25ºC?Because of the Enhanced Vapor Injection (EVI) technology from Copeland compressor, EUROSTARS designed EVI gas piping system and controlling system, make EVI air source heat pump can work stably in the low temperature condition.8.Customer visit us9.Air source heat pump delivery or container loading10.Installation instruction or installation photo, project photos
|