站内搜索
|
详细信息 Product Name: Vacuum Ion Plating Industrial Chiller Water Cooled Chiller Screw Chillers Model NO.: ESGW Series Condition: New Certification: CE Application Machine: Vacuum Ion Application Fields: Electroplating Noise Level: Low Compressor Number: 1 or 2 Selected Voltage: 220~480V-50Hz/60Hz-3pH Unit Structure: Integral Cooling Method: Water-cooled Type: Water-Cooled Compressor: Hanbell, Bitzer Chiller Color: White Condenser: Shell and Tube Evaporator: Shell and Tube Electrical Components: Schneider, FUJI Refrigerant: R22, R407c, R134A Controller: Touch Screen Microcomputer Control Expansion Valve: Danfoss, Emerson Starter: Wye-Delta Starter Hot Water: Heat Recovery Optional Capacity Control: Multi Steps Control Sight Glass: Emerson Service: OEM, ODM Trademark: ESACIR Transport Package: Wooden Pallet Specification: Cooling (with heat recovery optional) Origin: Shenzhen HS Code: 8418692090 Product Description Vacuum Ion Plating Industrial Chiller Water Cooled Chiller Screw Chillers1. Eurostars water cooled screw industrial chiller main components(1)Screw compressorScrew compressors are one version of positive displacement compression. As the screw rotors turn, the gas is compressed. Screw compressors have one or more rotors to accomplish the compression. Screw compressors feature simple and robust construction by elimination of some components such as pistons, piston rings, valve plates, oil pumps which are found in reciprocating compressors. Without these components,screw compressors run with low noise level, minimized vibration, high reliability and durability.(2)Evaporator*For smaller capacity chillers, the brazed plate evaporator is often used. The plates are stacked so they form a multi-layered design for two independent paths of fluid to travel. Each layer or path is linked to an inlet and outlet via a manifold at either end. The design of a brazed plate evaporator maximizes heat transfer at an attractive first cost for smaller chiller designs. The waterside of a brazed plate evaporator must be kept free of sediment and debris, strainers are required.*Shell ad tube evaporator is designed to be the refrigerant flows through the tubes and the water flows around the tubes inside the shell section. As heat is transferred to the colder refrigerant from the warmer water, the refrigerant in the tubes boils while the water is cooled. Baffles within while the shell direct the water flow path over the tubes to create turbulence, resulting in improved heat transfer.(3)Condenser*Water cooled chillers either use brazed plate or shell and tube heat exchangers for the condenser. As in the condenser, the refrigerant is on the shell side, and the fluid is on the tube side, the fluid is generally fresh water, used with an open cooling tower.*A typical condenser has a refrigerant hot gas inlet pipe and a liquid outlet pipe, the inlet pipe enters the top of the condenser where hot discharge gas from the compressor impacts a refrigerant distribution baffle.*Other condenser water sources include lakes, rivers, or cooling ponds, in coastal areas, seawater may also be used; however, appropriate materials, like titanium, should be used to minimize tube and tube sheet corrosion.(4)Expansion valve*To maintain the necessary pressure difference between the evaporator and condenser, some form of metering device must be used. Expansion valves use saturated suction temperature to regulate the amount of refrigerant that passed through them, and are typically controlled electronically.*Adopt superior quality famous exterior balanced thermal expansion valve, which is high reliability and adjustability, can realize precise refrigerant and temperature control to ensure operating in precise and reliable status.(5)Relief valvesRefrigerant relief valves on either the condenser, the evaporator, or both, are provided as safety devices in the event of overpressurization. Overpressuriztion might occur during a fire or if hot water were run through the chiller tubes.(6)Intellectualized controller*All chillers need to be properly controlled for safe and efficient operation. *Adopt micro computer touch screen control, can operate via centralized manage system; whole system can realize remote operation.*The system can monitor the water temperature,capacity status while running.The water temperature can be controlled according to the water outlet temperature.Trouble shooting code may display on the touch screen automatically when the system is abnormal.*PLC controller is optional.*RS485 interface reserved2. Eurostars water cooled screw industrial chiller brief introductionEurostars water cooled screw industrial chillersare depended upon to serve the process cooling needs of a wide variety of industries, and are selected due to their advanced designs which are focused on energy efficiency, reduction of water consumption, reduced maintenance, and improved reliability of both the cooling system and the processes and equipment it serves. It is widely used for the following industry:(1)Plastics:injection moulding, PET, blow moulding, woven sack extrusion,sheet and profile extrusion, thermoforming, presses, etc(2)Automobile and Mechanical Engineering machine tool, induction hardening and heating, welding machines, rolling mills, presses, cutting, profiling, polishing, electric discharge machine, hydraulic oil cooling, heat treatment, component washing, component cooling, environmental test chambers, drive cooling, plasma spray, vacuum systems, etc(3)Food and Beverages:Microbreweries, confectionary, bakeries, distilleries, wineries, bottling, carbonation, vegetable, meat and fish processing,(4)Medical MRI, PET scan, CT scan, linear accelerator, electron microscope, etc(5)metal working Water jet cutting, power press, hydraulic oil cooling, laser cutting, aluminium extrusion, precious metal processing, etc(6)Lasers cutting, welding, marking, profiling, optics, medical, engraving, etc(7)Paper and relatedprinting machine, labeling machine, cardboard making, plastic film machine, etc(8)Otherstextile, semiconductor, air compressor, concrete batching, dynamometer, furnace, etc3. Eurostars water cooled industrial screw chiller brief technical dataPleaseasksalesmanfordetailedcompletedataorvisitourwebsite:www.eurostarschina.comwww.waterchiller-unit.comIndustrial Water Cooled Screw Chiller (one compressor)Model ESGW-031ISON041ISON055ISON067ISON075ISON089ISON101ISON108ISON121ISON141ISonRated Cooling Capacity KW119158204279305361417456492582USRT33.845.058.179.386.6102.6118.5129.6139.8165.5×1000kcal/h102.1135.9175.6239.9262.0310.2358.5391.8422.9500.4Industrial Water Cooled Screw Chiller (one compressor)Model ESGW-162ISON175ISON183ISON208ISON230ISON234ISON278ISON297ISON392ISON443ISonRated Cooling Capacity KW68072475888296810391159145617141913USRT193.3206.0215.4250.7275.2295.4329.6414.0487.5544.0×1000kcal/h584.5622.9651.4758.0832.3893.2996.71252.01474.11645.1Industrial Water Cooled Screw Chiller (two compressors)Model ESGW-062IDON082IDON110IDON134IDON150IDON178IDON202IDON242IDON282IDON304IDonRated Cooling Capacity KW23731640855860972283498411641229USRT67.589.9116.1158.6173.3205.2237.1279.7330.9349.4×1000kcal/h204.0271.9351.1479.7524.0620.5716.9845.71000.81056.5Industrial Water Cooled Screw Chiller (two compressors)Model ESGW-324IDON350IDON366IDON416IDON460IDON468IDON556IDON594IDON784IDON886IDonRated Cooling Capacity KW1360144915151763193620782318291234293827USRT386.6411.9430.9501.3550.4590.7659.2828.0975.01088.0×1000kcal/h1169.01245.71302.91516.01664.61786.31993.42504.02948.33290.2Remarks:(1)Rated Cooling Capacity based on: Chilled water in/outlet temp. 17ºC/12ºC,Cooling water in/outlet temp. 30°C/35°C, Fouling factor: 0.088 sqm°C/KW.(2)Chilled Water Range: 5~20ºC; Cooling Water Range: 20~40ºC;4.Eurostars water cooled screw industrial chiller system solution5.Factory testing of Eurostars every chiller unit(1)Pressurization and helium leak detection of refrigeration circuit(2)Pressurization and leak testing of fluid circuit(3)Chiller performance and power consumption at full load(4)Proper operation of all controls, safety devices, and alarms(5)Electrical tests according to standards6.Eurostars water cooled chiller seriesWater cooled screw chiller(with dual compressors,dual condenser)Water cooled screw chiller(with single compressor, single condenser)Water cooled screw chiller(with flooded evaporator)Water cooled screw chiller with heat recoveryWater cooled heat pump chillerWater cooled heat pump chiller with heat recoveryWater cooled flooded screw chiller with heat recoveryWater cooled flooded heat pump chillerWater cooled centrifugal water chiller7.Why choose Eurostars?(1)Brand advantageOur brand: ESAICR. The high quality products come from focusing on brand cultivation, maintaining the brand and integrity in the end. To be one of the many proud brands of Chinese enterprise is our constant pursuit.(2)Product advantageHardware: from the case to some parts by CNC processing equipment, it is better to control the source material components.Software: famous brand control panel, electronic expansion valve can be selected, user-friendly operation interface, better energy saving control(3)After-sales advantageFrom product consultation to after-sales follow-up, we adopt a one-man to multi-post system for after-sales assembly. First-line personnel quickly connect to the fault situation reported by the client at the site. Internet multimedia records and video follow-up solutions to solve the on-site service.8. Eurostars Company Ceritifcates & Customer VisitingWe, EUROSTARS, which established in year 2006, is amodern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.9. Our factory viewModern new process and assemble line, including copper tube straighten machine, aluminum fin punching machine, three dimensional copper tube bending machine, tube expander machine, sheet metal laser cutting machine, numericalcontrol punching machine, CNC bending machine, chiller, fan coil unit and AHU assemble line,.etc..10. Eurostars water cooled chiller package and delivery(1)Multiple packing: proved by tests of the compression resistance, throwing. And highly secured.(2)Plywood case packing: High resistance of burst strength, ring crushing strength and tearing strength.(3)Wooden frame parking: Damp-proved and high resistance burst strength and ring crush strength.11. Eurostars water cooled chiller projectsWe exported chillersto Ukraine, New Zealand, Guatelmala, Peru, Chile, Norway,Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Sri Lanka, India, Saudi Arabia, Iran, Mexico, Argentina, etc..
|