Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

Shenzhen Eurostars Technology Co., Ltd.  

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:John
  • 电话:86-755-23205348
  • 传真:86-755-23205349
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > Ceiling Cassette Fan Coil with Remote Controller (EST300C2)
Ceiling Cassette Fan Coil with Remote Controller (EST300C2)
单价 $150.00 / Piece对比
询价 暂无
浏览 54
发货 Chinaguangdongshenzhen
库存 6000Piece
过期 长期有效
更新 2020-04-23 00:55
 
详细信息
Product Name: Ceiling Cassette Fan Coil with Remote Controller (EST300C2) Model NO.: EST300C2 Condition: New Certification: CE, SGS Lifetime: >20 years Mounting: Ceiling Mount Application Fields: HVAC for Restaurant/School/Building/Hotel Noise Level: Low Operating Voltage: 110V/220~240V-50Hz/60Hz-1pH Corrosion Durability: Higher Air Tube Material: Plastic Casing, Galvanized Sheet Unit Body Type: Fan Coil Unit Fan Coil Type: Ceiling Cassette Fan Coil Unit Pipe System: Two Pipe and Four Pipe System Air Outlet: 1 Way or 4 Way or Multi Way Water Inlet/Outlet Pipe Size: Zg 3/4" Trademark: Eurostars Transport Package: Standard Export Packing, Such as Cartons Specification: CE Approval Origin: Guangdong, Prc. HS Code: 84159010 Product Description Ceiling Cassette Fan Coil with Remote Controller (EST300C2)Eurostarsfan coil unit series((1)Wall mounted split fan coil unit(2)Ceiling floor fan coil unit(3)Horizontal concealed ceiling duct fan coil unit(4)Horizontal exposed fan coil unit(5)Ceiling cassette fan coil unit(6)Vertical exposed fan coil unit(7)Vertical concealed fan coil unit1. Ceiling cassette fan coil unit features:(1)Ultra-low noise; (2) High efficient and energy saving; (3) Strong air flow; (4) Easy installation and oeration; (5)Ingenious design.In central air conditioner system, Eurostars ceiling cassette fan coil unit continuously exchanges the indoor air with cool & heat supplied by chiller system, in order toadjust the room temperature and humidity. Ceiling floor fan coil is widely appliated in bureaux, business building, superstore, hotel, hospital, bank,apartment and amusement place.2. Ceiling cassette floor fan coil unit nomenclatureES T 600 C2 K4 Q 0 A O1 2 3 4 5 6 7 8 91: ES Eurostars2 :T Terminal series3 :600 Rated air flow: CFM4 :C2 Cassette type and the number of tube system5 :K4 Air outlet: K4-Four way; K1-One way; K2-Two way; K-Multi way 6 :Q Drainage way: Q-Forced drainage, electronic control; V-Forced drainage, electronic control, built-in water valve S-Natural drainage, no control; H-Natural drainage, electronic control7: 0 Inbuilt electrical heating: 0-None; 1-Electrical heating power 1.0KW (so on and so forth)8: A Power supply: A-220V-50HZ; K-208~230V-60HZ; N-115-60HZ; W-265~277V-60HZ9 :O Sales region: O-Other regions; C-Mainland China3.Ceiling cassette fan coil unit techinal specificationPleaseasksalesmanfordetailedcompletedataorvisitourwebsite:www.eurostarschina.comCassetteFanCoilUnit(4-way 2pipesystem)Model EST~200C2300C2400C2500C2600C2800C21000C21200C21400C2Powersupply220V,50Hz,1PhAirflow(m3/h)H34051068085010201360170020402380M2803805156607651040128015501800L18026034043053071086010501280StaticpressurePa000000000CoolingcapacityTHHW18002700360045005400720090001080012600BTU/h6142921212283153541842524566307083685042991SHW131119712700318441965362670780729070BTU/h447367259212108641431718295228842754230947THMW1500246030003715442364357848929610500BTU/h5118839410236126761509121956267773171835826SHW99415551995242630414236539366037190BTU/h33925306680782781037614453184012252924532THLW139120572479292137935604722385348900BTU/h47467018845899661294519121246452911830367SHW82312001530182623733284441652485500BTU/h2808409452206230809711205150671790618766HeatingcapacityHW2700405054006750810010800135001620018900BTU/h92151382318430230382764536860460765529164506MW194927703938490256947924104731299713900BTU/h6652945413440167311943427045357444435947441LW129717742779350538765421699286459700BTU/h442760559485119631322918502238642950533106NoiseHdB(A)373941434546485051PowerinputHW3752627696134152189228WaterflowHm3/h0.310.460.620.770.931.231.541.852.16WaterresistancekPa11.811.822.42729.629.635.435.440PipeInletwaterpipeZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"OutletwaterpipeZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"CoiltypeHydrophilicaluminumfinaroundshighefficientcopperpipeWorkingpressureMPa1.6Condensationwaterpipemm¢26¢26¢26¢26¢26¢26¢26¢26¢26Dimension NaturalDrainageL×W×H mm590*590*420752*752*443822*822*405822*822*443ForcedDrainage590*590*270752*752*293822*822*260822*822*293Panel650*650*45850*850*45950*950*45N.W. NaturalDrainagekg191920232325282829ForcedDrainage191920262628313132Panel2.24.56CassetteFanCoilUnit(4-way 4pipesystem)Model EST~200C4300C4400C4500C4600C4800C41000C41200C41400C4Powersupply220V,50Hz,1PhAirflow(m3/h)H34051068085010201360170020402380M2803805156607651040128015501800L18026034043053071086010501280StaticpressurePa000000000CoolingcapacityTHHW135020302700338040505400675081009450BTU/h460669269212115331381918425230312763732243SHW101015202080245032304130516062206989BTU/h34465186709783591102114092176062122323846THMW113018502250279033204830589069707873BTU/h38566312767795191132816480200972378226863SHW77012001540187023403260415050805532BTU/h2627409452546380798411123141601733318875THLW104015401860219028404200542064006674BTU/h3548525463467472969014330184932183722772SHW6309201180141018302530340040404234BTU/h215031394026481162448632116011378414446HeatingcapacityHW108016202160270032404320540064807560BTU/h36865529737292151105814744184302211625802MW78011081575196122783170418951995560BTU/h2662378253756693777510819142971774418976LW5197101112140215502168279734583880BTU/h17712423379547855290739995461180213242NoiseHdB(A)373941434546485051PowerinputHW3752627696134152189228WaterflowvolumeCoolingTubeHm3/h0.230.350.460.580.690.931.161.391.60HeatingTube0.090.140.190.230.280.370.460.560.70WaterresistanceCoolingHkPa8.268.2615.6818.920.7220.7224.7824.7840Heating3.543.546.728.18.888.8810.6210.6216InletwaterpipeCoolingtube/HeatingtubeZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"OutletwaterpipeZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"CoiltypeHydrophilicaluminumfinaroundshighefficientcopperpipeWorkingpressureMPa1.6Condensationwaterpipemm¢26¢26¢26¢26¢26¢26¢26¢26¢26Dimension NaturalDrainageunitL×W×H mm590*590*420752*752*443822*822*405822*822*443ForcedDrainageunit590*590*270752*752*293822*822*260822*822*293Panel650*650*45850*850*45950*950*45N.W. NaturalDrainageunitkg191920232325282829ForcedDrainageunit191920262628313132Panel2.24.56Note:(1)Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.(2)Heating: Inlet air temperature DB 21°C, heating water inlet temperature 60°C (tested by the same water flow with cooling condition).(3)The noise level is measured in: background noise 11.5Db(A) semi-anechoic room as per GB/T19232-2003.(4)Rated air flow is tested in standard air condition with DB 20ºC.(5)Specifications are subject to product improvement and change without notice.4. Eurostars Ceiling cassette fan coil unit photos viewing4. EurostarsCeiling cassette fan coil unit dimension5.Ceiling cassette fan coil unit installation illustration